In-Row Liquid-to-Liquid CDU

The In-Row Liquid-to-Liquid CDU integrates control, pump power, buffering, and heat exchange functions into a single unit. Through a circulation pump, the coolant with constant pressure and flow rate is continuously delivered to the supply-side pipeline and evenly distributed to server cabinets via the looped piping network.
Contact Us

Details

The In-Row Liquid-to-Liquid CDU integrates control, pump power, buffering, and heat exchange functions into a single unit. Through a circulation pump, the coolant with constant pressure and flow rate is continuously delivered to the supply-side pipeline and evenly distributed to server cabinets via the looped piping network. After absorbing heat from server nodes, the cooling medium flows back through the return-side pipeline and exchanges heat with the primary-side coolant through the CDU heat exchange module. The heat is then transferred to the external environment. The cooled medium returns to the circulation pump, is pressurized, and re-enters the supply-side loop, forming a closed-loop cooling system.

 

PRODUCT FEATURES:

◆ Cooling capacity range: 300–2300 kW, suitable for large-scale data center.
◆ Redundant safety design for key components, supporting online maintenance.
◆ N+1 redundancy for pumps, control sensors, and secondary-side filters.
◆ Dual power inputs, optional ATS support.
◆ Three control modes: differential pressure, constant flow, and constant temperature.
◆ SUS304 stainless steel piping, high reliability and  coolant compatibility.
◆ Compatible with both top and bottom piping on primary and secondary sides.
◆ Integrated real-time water quality monitoring (pH, conductivity, turbidity)
◆ 7’’ LCD touch screen with PLC controller and integrated monitoring of temperature, flow, pressure, leakage, and liquid level.
◆ Supports Modbus RTU, Modbus TCP/IP, and SNMP protocols.
◆ Three-level alarm mechanism for rapid fault diagnosis.

 

BEEHE IN ROW L2L CDU TECHNICAL PARAMETERS:

 

Product Mode

IB300

IB600

IB1350/IB1350P

IB1800

IB2300

OCP Deschutes

IB2000

Rated Cooling Capacity

300kW

600kW

1350kW

1800kW

2300kW

2000KW

Cooling Medium

PG25

PG25

PG25

PG25

PG25

PG25

Approach Temperature

5

5

4℃

4℃

4℃

3

Primary-Side Inlet/Outlet  Temp.

35℃/46℃

35℃/43.2℃

35℃/47.5

35℃/45.2℃

35℃/45.2℃

37℃/52.9

Secondary-Side Supply/Return Temp.

40℃/51℃

40℃/50.1

39℃/53

39℃/50.3℃

39℃/50.3℃

40℃/55.9

Secondary-Side Rated Flow Rate

445LPM

900LPM

1440LPM/1800LPM

2400LPM

3450LPM

1893LPM

Flow Rate Range

10-100%

10-100%

10-100%

10-100%

30-100%

40-100%

Available External Head

21.7PSI

36PSI

36PSI

42PSI

42PSI

80PSI

Power Supply Input

3P AC380V 50/60Hz

3P AC480V 60Hz

3P AC380V 50/60Hz

3P AC480V 60Hz

3P AC380V 50/60Hz

3P AC480V 60Hz

3P AC380V50/60Hz

3P AC480V 60Hz

3P AC380V50/60Hz

3P AC480V 60Hz

3P AC380-480V 50/60Hz

 

Maximum Power Consumption

≤5.5kW

≤12.2kW

19kW / 25kW

32.8kW

40kW

74kW

ATS

Yes

Yes

Yes

Yes

Yes

Yes

Pump Configuration

1+1

1+1

1+1

1+1

1+1

1+1

Secondary-Side Filter

100μm

50μm

50μm

50μm

25μm

25μm(Side stream is 0.2μm@3GPM)

Primary-Side Filter

500μm

500μm

500μm

500μm

500μm

500μm

Communication Protocol

Modbus RTU&TCP/

IP&SNMP

Modbus RTU&TCP/

IP&SNMP

Modbus RTU&TCP/

IP&SNMP  

Modbus RTU&TCP/

IP&SNMP

Modbus RTU&TCP/

IP&SNMP

Modbus RTU&TCP/

IP&SNMP

Group Control Function

Yes

Yes

Yes

Yes

Yes

Yes

Liquid Quality Monitoring Function

Yes

Yes

Yes

Yes

Yes

No

Automatic Refill Function

Yes

Yes

Yes

Yes

Yes

No

Net Weight

1297Ibs

1763.7Ibs

3351.1Ibs / 4708Ibs

5070.6Ibs

5342.9Ibs

5310Ibs

Dimensions (W × D × H)

600 x1200 x2300mm

800 x2000x2000mm

900 x1450 x2100mm /

1200*1800*2100mm

1200 x2000 x2000mm

1200 x2000 x2300mm

1651 x1061 x2242mm